Concentric Tube Heat Exchanger Manufacturer,Supplier and Exporter in India

Product Code : EL-HTL-11091

Specifications:
Inner copper tube I.D, 12.7mm. and outer G. I. Pipe I. D. 15mm. approx. and 1.5m. length.
Thermometers – 4 nos.
Measuring flask – 1 Lit. capacity.
Geyser-3 kW. Single phase.

Description :-
The apparatus consists of two concentric tubes. 
Inner tube consists of copper tube through which hot water flows. 
While the outer tube consists of GI pipe through which cold water flows. 
The arrangement enables the parallel and counter flow of the cold water. 
The inlet and outlet temperatures and the flow measurement enable to find out the heat exchanged LMTD, and effectiveness of the equipment.

Services required-
220v, 15A, stabilized single-phase AC supply.
Floor area – 3m x I m x 1 m height.

   